  1. i think BC means bottom contineous , BE means bottom extra , similarly TC and TE means top contineous and top extra
  2. what modifiers are you taken , 0.7 (uncracked) or 0.35 (cracked) , you have to check first your shear wall stresse with rupture stress fr=7.5(f'c) in psi , if wall stresses exceeds from fr than you have to take wall as a cracked section i.e 0.35 modifier otherewise 0.7 is o.k , as per ubc code. when wall modifiers changes from 0.7 to 0.35 , make wall to attracts lesser forces , by which its starts to pass in shear , but it depends on how much force is taken by shear wall
  3. I have done some calculation , after review some book , any comment would be appreciable drift check.pdf
  4. use staggered bar detailing at lap joint , by doing this , you can provide 5.25% steel in column instead of 4%, at lap joint column steel from above story will be half , so total steel at lap will be 5.25+5.25/2= 7.875% , which is less than 8% for IMRF . This detailed not applied to SMRF , as code restricted max column steel < 6%
  5. Aslamwalekum to all, Building base shear as per UBC is calculated from equation 30-4 to 30-7 as shown in first image , but for drift it allows to ignore eq 30-6 as shown in 2nd image and calculate base shear on time period of Method B eq (.30-10) . My question is if model a building in ETABS , It calculate base shear from equation 30-4 to 30-7 , so how can i make ETABS to ignore eq (30-6) for drift calculaton only.
  6. Sorry , i was looking at print table summary report , but yes you were right it shows in print table input options thanks
  7. Dear asad Thanks for reply , unfortunately i am using ETABS 9.7.4 , which dont show this option , please see attached image , i will great full to you, if you help me with this version
  8. Aslamwalekum to all, I want to check my building base shear , ETABS give its calculation in summary report which is shown in attached image but, in few models it dont show these calculation , can somebody review it and suggest what is the problem in my model. the ETABS model and its summary report is attached with it BEHRIA TOWN-ETABS-9-10-2019-REV-47-PART-1.final.e2k LOADING.txt BEHRIA TOWN-ETABS-9-10-2019-REV-47-PART-1.final.e2k LOADING.rar
  9. As per our office practice, we add shear r/f with torsion , for flexure we divide torsion r/f by 2 , then add this r/f in top and bott longitudinal r/f
  10. if you want to model a beam as simply supported beam , then you will need to end realese , so the beding moment draw as for simply supported beam, other wise without relase , depending upon the stiffness , negative and positive both moments comes in beam
  11. you can download from below link https://de.usembassy.gov/wp-content/uploads/sites/21/2016/08/Attachment-J.2-2015_OBO_Building_Code1.pdf
  12. commonly raft have bearing capacity on 2in settelement , while isolated footing have bearing capacity on 1 in settlelemt, so diifinitely bearing capacity at 2in settlement would be greater than bearing capacity at 1inch settlement
  13. stone column and vibro compaction are the techniques use in my city (KARACHI), but the technique depends on soil condition
×
×