Jump to content
Structural Engineering Forum Of Pakistan

Hussain Abid

Member
  • Content count

    68
  • Joined

  • Last visited

  • Days Won

    1

Hussain Abid last won the day on January 12 2017

Hussain Abid had the most liked content!

About Hussain Abid

  • Rank
    Lieutenant

Profile Information

  • Gender
    Male
  • Location
    Pakistan
  • University
    Q.U.E.S.T
  • Employer
    Private
  • Interests
    STRUCTURAL ENGINEERING

Recent Profile Visitors

520 profile views
  1. Hussain Abid

    Detailing ???

    Attachment Deleted
  2. Hussain Abid

    Exporting ETABS to Safe

    Thanks for the reply.in order for more precise understanding of the subject topic i share a link.if time allows, kindly reply 'YES'. The link is
  3. Hussain Abid

    Exporting ETABS to Safe

    Dear experienced fellows After completing the model in Etabs, what's the next step for foundation design. What i have learnt is that: 1- Do we have to import the Edb file into SAFE? I didn't get this point of modelling foundation in Etabs coz i have learnt that foundation is modelled in SAFE only 2- we have to get the forces value i.e Factored axial loads and bi axial moments from reactions in ETABS and design foundation in SAFE accordingly? Thnx in anticipation
  4. Hussain Abid

    ACI detailing and design manual

    Bundles of thaks
  5. Hussain Abid

    ACI detailing and design manual

    im attaching screenshot for the beams b/w grids F &H. im unable to make out the three values 0.9,0.2,0.9 and 0.6,0.6,0.4. These values show the top and bottom reinforcement values, how to interpret these values?
  6. Hussain Abid

    ACI detailing and design manual

    It would be nice if you could elaborate the same case with beams reinforcement.
  7. Hussain Abid

    ACI detailing and design manual

    Thnx for your valuable comments.
  8. Hussain Abid

    Live Load Reduction

    LIVE load option in static load cases is assigned when we have parking load on floors, otherwise assign REDUCIBLE LIVE load option for normal load occupancy i.e movement of people, luggage etc.
  9. Hussain Abid

    ACI detailing and design manual

    Aoa dear experienced fellows. Can anyone let me know how can we do the detailing of a 15"x30" rcc column with 4.5 in2 of Ast. Do we have to use ACI SECTION 7.7 Equations for the purpose or any other fomula or thumb rules etc. Any suggestions in this regards are highly appreciate. Thnx
  10. Hussain Abid

    Live Load Reduction

    Dwar Baz in the above link file not found.we usually select Tributary Area for L.L.R,can sm1 explain why its done and wat abt other options like Influence area etc.thnx
  11. Hussain Abid

    Help required for analysis in etabs

    Dear all,i found out the reason why column reinforcement was 1℅ in all columns and it was that i had erroneously assigned oversized column dimensions in some columns. But my second querry yet remains unanswered that is whether the building be modelled as a whole or separated into two portions in order to avoid errors.thnx n regards
  12. Hussain Abid

    Help required for analysis in etabs

    Dear waqar I'm uploading architecture and edb file of the model.i have separated the building by providing expansion joint.the file in etabs model is one portion of the building, I'm working on it.secondly if we dont want to provide expansion joint thn wat to do? coz when i model the entire building then lots of errors are coming so i separated the building now there aren't any errors.all suggestions will be highly appreciated.thnx n regards STATIC MODEL.EDB STATIC MODEL.$ET AMMALGAMATION PLAN-Model.pdf
  13. Hussain Abid

    Stiffness Method

    R.c Hibbeler's structural analysis is also worth reading and enjoying 😁
  14. Hussain Abid

    Help required for analysis in etabs

    Dear Uzair, I'm also facing the same problem.my building is in zone 2A,soil sd,all spans are less than 25ft,slab thickness 6",size of columns and beams are 12"x30" and 9"x18" respectively. Seismic load cases are 4. End result is all columns are having steel 1%.is it ok to have same %age in all columns? Or something is definitely wrong? Secondly building shape is pretty regular and no of stories are eight.rigid diaphragm assigned.etabs version 9.7.5. but i just remember i erroneously defined 25% live load in mass source command as the building is for purely residential purpose as against Warehouse or a garrage where we define 25% of L.L.?
  15. Hussain Abid

    Time Period

    Thnx a lot for ur kind co operation.i ll check it
×

Important Information

By using this site, you agree to our Terms of Use and Guidelines.