Jump to content

Search the Community

Showing results for tags 'Column Shear'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • General
    • Member Introduction
    • Shout Box
    • Students Zone
    • Engineering Marvels & Disasters
  • Civil/ Structural Engineering
    • General Discussion
    • Steel Design
    • Concrete Design
    • Seismic Design
    • Foundation Design
    • Software Issues
    • Journal/ Articles/ Tutorials
    • Spreadsheets & Softwares
  • Technical Support
    • Website Announcements/ Problems/ Login/ Registration Issues
  • PSX Stocks Investing's Topics
  • Parenting's Topics
  • Construction Consulting's Industrial Construction Project
  • Construction Consulting's Piling

Calendars

  • Community Calendar
  • Construction Consulting's Piling

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Website URL


Skype


Location


University


Employer


Interests

Found 2 results

  1. Asalamualaikum, If I know any column section, I can compute its section capacity in terms of yield moment using SAP section analysis or Response 2000 softwares. But if I want to find whether a column is failing in shear or not, what procedure should I use? For example, I have a column of 6'' x 18'' with 6 #4 bars and ties of #3@6'' c/c. I have done pushover analysis on software, Now I want to check whether column is safe in shear or not. So I note down the internal shear forces of column from the software at each step of pushover analysis and manually compare them with column shear capacity using ; Column shear capacity = Shear force resistance due to concrete (2 * lamda* fc'^1/2 * bd) Is this the correct method? or do I need to consider ties as well in resisting shear? If yes, then Vs=Avfyd/s formula will be used for ties resistance or something else? Thanks for the help
  2. MIDAS SET Column Concrete Shear Capacity Problem MIDAS SET 3.2.1 Column Concrete Shear Capacity Problem Link for CIVILEA topic MIDAS SET is a good tool to verify individual sections output. It incorporates a simple input data form on the left side and the detailed equations and output in the right pane. Despite of its good tools and features, I faced a problem while I was calculating the column shear capacity (concrete) manually and trying to verify it with MIDAS. To my astonishment it gave me almost double the value which I got using ACI-318 chapter 11 equation 11-4 for concrete shear capacity under axial loads. I will show you here the detailed steps to prove my point. If you find anything misleading or want to share your thoughts please respond. I have written an email to MIDAS and let’s see when can I get the response. Solve a simple column example B=500mm H=500mm Cover=50mm so d = 450mm Axial Factored Load is 700kN Compression f’c = 45 MPa Ag = 500x500 = 500 mm² From ACI-318(05M) chapter 11, equation 11-4 we get; Vc = 0.17 (1 + Nu/14Ag) (f’c^0.5) b.d Where Nu/Ag term should be in N/mm² Nu is –ve for TENSION and +ve for compression So putting all these values in this equation we get; Vc = [ 0.17 ( 1 + 700*1000/14/500² ) (45^0.5) 500 x 450 ] / 1000 = 307.91 kN and Phi Vc = 0.75x307.91 = 230.93 kN whereas in MIDAS software, it gives Phi Vc in both the directions equal to 612.0 kN. This value is even more than 2 times the value we calculated from ACI equation. I am doubtful to use this software for verification because of this error.
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.