Jump to content

Search the Community

Showing results for tags 'Slenderness'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • General
    • Member Introduction
    • Shout Box
    • Students Zone
    • Engineering Marvels & Disasters
  • Civil/ Structural Engineering
    • General Discussion
    • Steel Design
    • Concrete Design
    • Seismic Design
    • Foundation Design
    • Software Issues
    • Journal/ Articles/ Tutorials
    • Spreadsheets & Softwares
  • Technical Support
    • Website Announcements/ Problems/ Login/ Registration Issues
  • PSX Stocks Investing's Topics
  • Parenting's Topics
  • Construction Consulting's Industrial Construction Project
  • Construction Consulting's Piling

Calendars

  • Community Calendar
  • Construction Consulting's Piling

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Website URL


Skype


Location


University


Employer


Interests

Found 2 results

  1. Assalam-o-Alaikum! Dear All, Do ETabs apply slenderness ratio check in Column Design using ACI 318. If not, then what is the solution as sometimes moment is magnified significantly due to M2,min although it is a short column.
  2. May be my questions seem stupid but just for the sake of disucssion today I have posted this to Mr. Arshad Khan, Civilea forum and SEFP forum. Looking forward to arrange all the answers by you guyz and write a tutorial Dear all, I have following question regarding slenderness in ETABS 1) Why moment magnification method and 2nd order elastic method both are used by ETABS. I mean in ACI there are 3 methods to do (any of them) then why we put modifiers and then ETABS calculates internally the moment magnification factors. 2) If structure is braced then how to stop etabs from calculating moment magnification? 3) If drift limits are defined for example in ASCE H/400 then why is the need to perform P-delta. If we control the drifts to be H/400 still we need to perform p-delta? 4) We take wind drifts for 10 year return period. that is multiplying 0.7 to W of 50 year year..to convert this into service level....What type of modifiers are required to be put in ETABS to take drift or deflections on this 10 year Wind.. Serive modifiers Beam=0.5 & Column=1.0 or Ultimate modfiers Beam=0.35 & Column=1.0 I mean as per ACI we can multipy the deflections from ETABS to 1.43 if we use strength level modifiers?
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.