  1. UmarMakhzumi

    DUAL SYSTEM

    Save your model as a new file. Using stiffness modifiers reduce stiffness of wall and apply 25% base shear to the frames only to make sure they don't fail. Thanks.
    1 point
  2. WR1

    DUAL SYSTEM

    Reduce the stiffness of shear walls such that the base shear carried by columns is 25%.
    1 point