Jump to content

Fawad

Member
  • Posts

    11
  • Joined

  • Last visited

Everything posted by Fawad

  1. 1) ETABS calculate Positive moment by taking 75% of Live load plus full dead load but my point is that if our applied live is huge like 200psf and Dead load (finishes Load+Slab self wt) is 150 and having long span of about 35ft. The positive design moment will be very much conservative because of the difference in wL2/8 and wL2/24. So if we reduce the PLLF in ETABS from 0.75 to 0.5 or less. Would this approach will be correct ????? Thanks for your time & guidance..
  2. @Rana Please explain the Pattern Live Load Factor effect on design of beam bottom reinforcement. wouldn't the bottom design reinforcement for a continuous beam be very high/conservative than that required based on analysis, if calculated based on wl2/8 ???
  3. Thank you @Husam for your efforts and sharing your Trial model. I have checked the model and few questions to ask. 1) Normally we have only bearing capacity available from client to design foundation. So how to calculate Area springs value from that bearing capacity. 2) Your model is not calculating Punching Shear. It displays N/C. 3) Please explain the Isolated Column Footing and soil profile options given in Define ---> Spring Properties ---> soil profile and isolated column footing. Thanks
  4. Need clarification regarding difference in ETABS analysis and design moments. Why ETABS design & analysis moment under the same combo i.e UDCON2 is different. (See photo attached) Moment diagram shows 1809 kip-ft while ETABS is taking 2590.69 kip-ft for reinforcement calculation. The design moment is also different from the envelop combo i.e 1809+642=2451 kip-ft Thanks
  5. Thank you @asadishaq Is there any code reference for shrinkage strip ?? Architect is not allowing for any expansion joint in a plan of area 80mx50m. Normally grid to grid spacing is 12mx12m panel over the area of 80mx50m. Thermal expansion of 80m long concrete comes approx 32mm with 40 degree Centigrade change in temperature. Coefficient of thermal expansion of concrete is 9.9e-6 per degree centigrade. i.e (80x1000)(40)(9.9e-6)=32mm I have provided top reinforcement more than required at the roof slab and provided an expansion gap of 100mm in my 80mx50m structure with nearest existing building. Am i doing it right ???
  6. How to check this limit of 1.4 in ETABS.
  7. Thank you sir @BAZ, As all my other serviceability checks like drift and deflections are in code allowable limit, so i just amplified/override the eccentricity of my EQX and EQY in load pattern by torsion amplification method as per UBC97 and designed my vertical members accordingly. Please guide/correct me if i am missing something. Jazakallah
  8. Aoa, Thank you all the seniors for providing such a nice learning platform. I am working on the design of a 3 story structure (2 basements+Ground Floor). Base level is at -10m from grade level while top roof (ground top) is +8m from grade level. Total covered area of building is 100mx60m which is divided into 4 blocks i.e 50mx30m each (See pic attached). Basement retaining wall is provide only at two orthogonal sides (one long and one short side) of each block. But this two sided retaining wall is creating extreme torsion irregularity in my structure. Normal span length is 12m. So my question is that can i ignore this two sided basement wall in my model ? because this is below grade level and would not contribute in resisting EQ.
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.