Jump to content

Mian Muhammad Aslam

Member
  • Posts

    4
  • Joined

  • Last visited

Profile Information

  • Gender
    Male
  • Location
    Islamabad
  • University
    UET
  • Employer
    CSG
  • Interests
    Structural Design

Recent Profile Visitors

The recent visitors block is disabled and is not being shown to other users.

Mian Muhammad Aslam's Achievements

Newbie

Newbie (1/14)

0

Reputation

  1. Thanks for the document, it is useful to see the properties of blocks. We have been using such insulated blocks in UAE for long time. They provide good insulation and same time you can design load bearing walls too by some types of those blocks.
  2. Dear Col. Ayesha Sahiba, Thank you for the information you have shared, I have gone through, it is useful. I see they have used the in-fill of block walls of 300Psi between the concrete frame structure which is bit similar to the schematic design of our panel, and rest of the frame structure is as normal as we already work with. However, configuration of our panel is bit different. We aim to have the beams and columns built-in as precast in a composite panel (panel configuration is attached herewith for your ready reference). The structural frame will come readily built-in the panels, each element will be very well connected as described earlier and shown in the attached sections, the slab will be concreted at situ to have monolithic structure. You know that this will increase the quality of construction to the maximum as the panels would be built in the factory under highly controlled environment and erection at site will be done within the provisions made in the panels. Now, coming to the design calculations and achieving the optimum configuration to reduce the cost as much as possible we are looking for ETABS tool(s) to run as many times it is needed. We again tried to use the same tools which are used to analyze and design that 6-floor building of NED but it gives different results. I am sure ETABS would have such tools, being exert of ETABS if you can help us in this regard, will great. Once again thanks and best regards. Aslam Panel Design.pdf
  3. Thanks for your valid observations. Yes, there are a few elements which I supposed to mention which are follows: 1- The panels would not only be connected at four corners only to the plinth beam or foundation, if so, you are right; in such case we cannot transfer the sheer forces on the joints. Actually, both side layers of each panel have reinforced concrete connectivity at every 45-60 cm, which will increase the effective stiffness of overall panel to counter the buckling as well as to cary the load of beam and slab to the foundation. In addition to that these connectors will have the rebar dowels inserted coming out of the plinth beams or foundation. These inserted rebar dowels will be grouted with special grout having compressive strength of no less than 30-40N. 2- Insulation is required to be of 100 cm think in order to increase the thermal insulation and to decrease the thickness of side layers concrete to 50 mm with concretors at 450-600 mm C/C. These elements of concrete (layers and connectors) will be made of high-performance concrete with increased ductility. Instead of considering 150mm thick simple sheer wall, we need to run it as a composite panel as mentioned, in order to acheive good ecconomy scale. This is the reason we need to run it in ETABS with different configration of this panwl to acheive the optimum thickness of the layers and connectors. 3- Moreover, it is important to note that this concept will provide a highly effective bracing system, bracing all the beams and corner columns diagonally at both levels (top and bottom) which works well to counter high lateral loads. Herewith attached is the section of panel for clearer picture. Panel Design.pdf
  4. Wall panels are required to be designed which should be load bearing as well as insulated. A concept is developed to build such panels with total thickness of 8” (20 cm), having two layers of high-performance concrete sheets on the sides filled with the insulation, each of these two sheets to be of 3-4 cm thick reinforced concrete, using welded wire mesh as reinforcement, both sheets should be linked with vertical reinforced concrete ribs (columns) placed at short distance, in order to; (1) provide enough stiffness against axial load and buckling, (2) carrying the built-in beam to transfer the load of slab and (3) the entire panel will work as bracing for the frame structure to take the lateral loads in seismic zones. In addition to that the house construction with such panels is assumed to be more economical than the overall brick and concrete structure. The question is that how can we perform the analysis and design calculation of such panels especially can we use ETABS to conduct such analysis and design calculations? If yes, please let me know how? As I have tried to find out in my ETABS 2016 but could not. There is a provision for core wall design but not the hollow insulated wall as mentioned above. Thanks and best regards. Aslam
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.