Search the Community
Showing results for tags 'Stiffness Modifiers'.
-
Hi, I need to provide pick up columns to support the landing beam of staircase. The story-level beams will also rest on these columns. The stiffness modifiers prescribed for columns by ACI is 0.7. I was wondering if I can reduce that to (say) 0.35 or less, since I don't want these columns to p...
-
The stiffness modifier for beams = 0.35I column = 0.7I and slabs 0.25I. they are required to consider the cracking of the members. my question is why do we consider 35% of stiffness for beams while code says we can use 70% of stiffness for columns? what is the significance of the numbers 35 , 70 , 2...
-
Hello, I need to know please what will be the stiffness modifiers values in ETABS for fully prestressed beam or slab in case of: - Wind Analysis - Earthquake Analysis Thank you in advance.
-
Hello I have a question regarding stiffness modifiers in ETABS. The code(ACI318) specifies us to use stiffness modifiers for walls column etc. What if I use 0.35 as stiffness modifier and not 0.7. What is the effect.I know that we have these stiffness modifiers based upon cracking of section an...
-
what should we take moment of inertia of shear walls either cracked or uncracked section?
-
I want to comment on some modelling issues in ETABS. Though some of these things are discussed elsewhere in the forum, I hope to extract some more useful conclusions. First thing is related to modelling the bending stiffness of flexural members, for strength level loads, that is representative...
- 5 replies
-
- stiffness modifiers
- baz tips
-
(and 1 more)
Tagged with:
-
*Comments/Observations regarding modelling in ETABS* *Doc No: 10-00-CD-0006* *Date: May 06, 2017* Some of the observations made during extraction of results from ETABS (v 9.7.4), for design of reinforced concrete members, are being share in this article., 1) Minimum Eccentrici...
-
- stiffness modifiers
- time period etabs
- (and 3 more)
-
aslamwalekum , when we design reinforced concrete elements , for beam we take 0.35 , for column and wall we take 0.7 and for slabs we take 0.25 as modifiers , but i read in aci that for servicibilty analysis these modifiers has to increase by 43% which means for beam it become 0.5 , for column and s...
-
Hi, i am a fifth year student working on my final project, it is a 59 floors + basements tower. I am having a weird problem; after applying the stiffness or property modifiers (0.35 for beams and walls, 0.7 for columns and 0.25 for slabs), i got an instability warning during analysis. After...
-
Hi; In ETABS model for designing columns and shear walls(because slabs will be desined on SAFE), I want to reduce m11=m22=m12=f11=f22=f22=0.25 Can I? (Semi rigid diaphragm assigned) thats because I want to design the building at same model for temperature and seimic and wind loads.
-
As beam Moment of inertia is 0.35 as per ACI code . if we taking it 35% then where is rest of 65% going ? Kindly give me concept of it , Similarly in Column we are taking it 70% what about remaining 30% ?